Mar 25, 2014 nycocard is a small device with a nycocard reader kit, which is the base for the boronat affinity binding test. Pdf comparative study of glycated hemoglobin by ion. Recent hba1c values and mortality risk in type 2 diabetes. Nycocard hba1c point of care ivd rapid diagnostics.
Dcct diabetes control and complications trial units measured in % ifcc international federation of clinical chemistry units measured in mmolmol the target hba1c value for most people with diabetes is 6. Nycocard hba1c the nycocard hba1c test is a 3 minute point of care test for the measurement of glycated hemoglobin. Introduction application certification and hba1c demo using this and handling. Hba1c, ion exchange chromatrography, nycocard reader, type 2 diabetes. The quotest hba1c system is a fully automated hemoglobin a1c analyzer that uses patented boronate. Besides monitoring hba1c is also recommended by international organizations as who and ada for reliable diagnosis of diabetes. Nycocard hba1c import data of india and price seair exim solutions provides the latest, 100% genuine and trusted indian import data of nycocard hba1c.
In vitro diagnostic medical devices only for professional use. Even if the hplc is the reference method for measuring the hba1c, it did not obtain a better reproducibility in eqa results than immunochemistry devices. Introduction to nycocard reader ii description of nycocard. Testprinzip nycocardhba1cisteinborataffinitatstest.
In addition, average blood glucose levels can be converted from mgdl to mmoll. Nycocard hba1c nycocard ualbumin nycocard crp nycocard ddimer. Hba1c values represents the average blood glucose level over the past 812 weeks and is used for longterm glycemic control in diabetic individuals. Nycocard reader ii wholesalers, dealers, suppliers in. A matched nested casecontrol study was implemented, within a cohort of participants with type 2 diabetes from 2000 to 2008. Nycocard reader for quantitative determination of crp hba1c ualbumin ddimer axisshield axisshield poc as pa rt of t he ax iss eld g up p. Hemoglobin a1c test the hemoglobin hba1c test measures the average amount of sugar glucose in your blood during the 23 months just before the test rather than measuring the current amount of glucose in the sample of blood. It will help you in many ways such as you can generate competitive analysis reports on importer, port, supplier and exporter of nycocard hba1c. Hba1c and ualbumin concluded the range of planned nycocard tests for the pointofcare market. The advantages and disadvantages of reporting hba1c results in the new ifcc range vs. Nycocard hba1c the nycocard reader ii is a small battery powered instrument, designed to measure all nycocard products. Whole blood sample was mixed with chemical reagent based on kit instructions and the final product was poured on a test device.
Hba1c is used to monitor long term glycemic control, adjust therapy and predict the risk for the development of late complications. Normal adult haemoglobin consists predominantly of hba 2 2, hba 2 2 2 and hbf 2 2. In 2004, the adaeasdidf working group of the a1c assay was established to harmonize hba1c reporting. Nycocard hba1c is rapid and provides an accurate hba1c result. Brochure hba1c glycated hemoglobin hypertension scribd. Comparative study of glycated hemoglobin by ion exchange chromatography and affi nity binding nycocard reader in type 2 diabetes mellitus. The hba1c test can be done in the ucsf pediatric diabetes clinic by using a fingerstick blood sample or the test can be performed in the lab by doing a blood draw from a vein. The reagent is original and produced by axisshield later acquired by alere the reagent is original and produced by the manufacturer. Nycocard hba1c import data india with hs code, nycocard hba1c.
Next, rinsing liquid was added and, finally, the result was read by the nycocard reader. With nycocard reader ii, healthcare professionals in hospitals and in general practice will obtain accurate, quantitative results from all nycocard tests. Oral magnesium supplementation in type ii diabetic patients. Nycocard reader ii is a small battery powered instrument. Study of glycated hemoglobin by ion exchange chromatography and affinity binding nycocard reader in diabetes mellitus poster pdf available december 20 with 283 reads how we measure reads. The nycocard hba1c test is a 3 minute point of care test for the measurement of glycated hemoglobin nycocard hba1c provides an accurate and reliable method to monitor metabolic control in people with diabetes. The nycocard hba1c test and the nycocard reader ii, give you reliable results conveniently available when and where you need them. Nycocard hba1c the first step to effective diabetes management. The hba1c test, also known as the haemoglobin a1c or glycated haemoglobin test, is an important blood test that gives a good indication of how well your diabetes is being controlled together with the fasting plasma glucose test, the hba1c test is one of the main ways in which type 2 diabetes is diagnosed. Comparative evaluation of three different methods for hba1c. Cobas b101, dca 2000vantage, hemocue, innovastar, nycocard, quolab, quotest.
Sep 14, 2011 on the other hand, the hba1c cv np % calculated for dca and integra diagnostic devices are similar to the cv published by the college of american pathologists in their 2010 gh2. Retrospective analysis of 55,769 hba1c eqa results obtained. Following is a chart showing the hba1c % and the corresponding estimated average blood glucose eag. Feb 09, 2016 glycated haemoglobin hba1c laboratory tests are used to diagnose diabetes mellitus and to assess control in diabetes mellitus. Alibaba manufacturer directory suppliers, manufacturers. Ddimer is a protein that is released into the circulation during the process of. The nycocard hba1c test is a 3 minute point of care test for the measurement of glycated hemoglobin. Measurement of glycated hemoglobin hba1c is central to the management of patients with diabetes. The more glucose in the blood, the more haemoglobin a1c or hba1c will be present in the blood. Nycocard hba1c, italy nycocard hba1c suppliers directory on.
Read the result within two minutes using nycocard reader. By measuring the hba1c it can tell you how high your blood glucose has been on average over the last 812 weeks. For further information regarding hba1c monitoring and targets, see the separate management of type 1 diabetes and management of type 2 diabetes articles. Italy nycocard hba1c, nycocard hba1c from italy supplier find variety nycocard hba1c from nycocard reader,dry chemistry analyzer,immunoassay analyzer, medicalray protective products suppliers located in italy, buy nycocard hba1c made in italy on. The calculator enables the conversion of hba1c values from % ngsp to mmolmol ifcc and vice versa. Nycocard reader instruction manual book free download as pdf file. Patient consultations can be carried out with confidence. During this time the nycocard reader and reader ii were also introduced, satisfying demand for automated reading of nycocard tests. Red cells live for 8 12 weeks before they are replaced. Euromedix health am dom gmbh koln, germany euromedix health care solutions ag zug, switzerland euromedix pointofcare nvsa leuven, belgium. The nycocard crp test is a 2minute point of care test to indicate bacterial or viral cause of infection. Nycocard reader instruction manual book calibration battery. You have clicked a page that seems to be very popular. Oral magnesium supplementation in type ii diabetic patients mehrdad solati 1, elham ouspid 2, saeedeh hosseini 3, nepton soltani 4 mansoor keshavarz 5, mohsen dehghani 6.
Jul 05, 20 this study aimed to evaluate mortality within 365 days of hba1c values of 9. The quotest is a fully automated desktop pointofcare analyzer designed for easy and reliable hba1c measurement for the monitoring and management of diabetes in a pointofcare setting such as diabetes clinics and doctors surgeries. A normal nondiabetic hba1c is nycocard reader for quantitative determination of crp hba1c ualbumin ddimer axisshield axisshield poc as pa rt of t he ax iss eld g up p. The coloured responses of the nycocard products are measured by spectral reflectance in three. By insertion of any value all other fields will update automatically. Ada gomero, university of chicago, department of obgyn thomas mcdade, northwestern university, departments of anthropology and cells to society c2s. Hba1c can be used as a diagnostic test for diabetes providing that stringent quality assurance tests are in place and assays are standardized to criteria aligned to the international reference values, and there are no conditions present which preclude its accurate measurement. The following chart makes it easy to convert old % units into the newer mmolmol units. Major players and key issues volume 1 company analyses. The nycocard hba1c test is a 3 minute point of care test for the measurement of glycated hemoglobin nycocard hba1c provides an accurate and reliable method to. Hba1c test for diabetes diagnosis, target hba1c, home tests. Some of the glucose that circulates in your blood binds to blood proteins. The association between hba1c and cardiovascular disease.
Nycocard crp measures creactive protein crp, an acute phase protein that increases rapidly after onset of infection. View detailed import data, price, monthly trends, major importing countries, major ports of nycocard reader ii. Hba1c for monitoring of diabetic control and increasingly disease diagnosis, ualbumin urine test for assessing degree of diabetic renal complications and creactive protein crp test for differentiation between bacterial and viral infections and whether antibiotic treatment is merited and ddimer for rapid determination of the fibrin degradation. The nycocard reader ii is a small battery powered instrument, designed to measure all nycocard products. Generally, the hba1c test is performed every three months. Nycocard reader ii welcome to amity healthcare ltd. Reagent dedicated to the nycocard reader ii to determine the glycosylated hemoglobin hba1c in the blood.